Triple Modality 3D Abdominal Phantom

Model 057A
CT/ ULTRASOUND/ MRI IMAGE FUSION• LIVE SCANNING• BIOPSY TRAINING

The CIRS Triple Modality 3D Abdominal Phantom is constructed of a self-healing formulation of Zerdine ®1 that allows multiple biopsy insertions with minimal needle tracking, and is ideal for demonstrating image-guided navigation technologies.

Abdominal imaging is useful for diagnosing disease and monitoring treatments. Our Model 057A is representative of a small adult abdomen and can be imaged under CT, MR and ultrasound. This feature makes the phantom a useful tool for applications such as image fusion studies; imaging protocol developments; scan technique training; and system testing, validation and demonstration.

The Model 057A simulates the abdomen from approximately the thorax vertebrae (T9/T10) to the lumbar vertebrae (L2/L3) using simplified anthropomorphic geometry. The materials provide contrast between the structures under CT, MR and ultrasound. The solid polymer background gel will not leak when punctured.*

Internal structures include the liver, the portal vein, two partial kidneys, a partial lung, the abdominal aorta, the vena cava, a simulated spine and six ribs. The liver has six lesions and the kidneys each have one lesion. A muscle layer and outside fat layer surround these structures and plastic end caps make the phantom durable enough for extended scanning. Blood vessels have CT contrast added to provide enhanced auto registration in image fusion applications

The Phantom includes a foam lined hard carry case. To accommodate image fusion techniques, the phantom can be purchased as a kit to include a serial-number specific CT DICOM Data set for reference. CIRS can also offer value-added options and services such as phantom specific CMM, attachment of customer specific registration devices and inclusion of special point markers

Features:
  • Demonstrate CT, ultrasound and MRI scan techniques
  • Assess image-fusion algorithms
  • Test new equipment
  • Optimize imaging protocols
  • Improve performance of freehand abdominal biopsies

(1)US Patent #5196343

NOTE: Some permanent tracking may be evident if debris and air bubbles are entrained in the gel during the biopsy procedure. To extend the lifetime of the phantom, the use of higher gauge needles that have been wetted and de-aired prior to insertion is recommended.

Data Sheet

Triple Modality 3D Abdominal Phantom: Data Sheet

Xiaofeng Lin, Shoujun Zhou, Tiexiang Wen, Shenghao Jiang, Cheng Wang, Jingtao Chen 'A novel multi-DoF surgical robotic system for brachytherapy on liver tumor: Design and control'. Computerized Medical Imaging and Graphics. 2021; 90: 101905. Pergamon. View
Al-Zu'bi, Shadi; 'Secure 3D medical Imaging'. arXiv preprint arXiv:2010.03367. 2020; View
Li, Ruotong; Tong, Yuqi; Yang, Tianpei; Guo, Jianxi; Si, Weixin; Zhang, Yanfang; Klein, Reinhard; Heng, Pheng-Ann; 'Towards quantitative and intuitive percutaneous tumor puncture via augmented virtual reality'. View
Yuan, Jing; Xue, Cindy; Lo, Gladys; Wong, Oi Lei; Zhou, Yihang; Yu, Siu Ki; Cheung, Kin Yin; 'Quantitative assessment of acquisition imaging parameters on MRI radiomics features: a prospective anthropomorphic phantom study using a 3D-T2W-TSE sequence for MR-guided-radiotherapy'. International Journal of Computer Assisted Radiology and Surgery. 2021; 16 (6): 1003-1014. Springer International Publishing. View
Konovalov, ME; Klimov, DD; Tohtamir, DP; Poduraev, YV; 'Approach to the Development of an Abdominal Phantom with the Function of Respiratory Motion for Robotic Surgery'. Quantitative Imaging in Medicine and Surgery. 2021; 11 (5): 1870. AME Publications. View
Xue, Cindy; Zhou, Yihang; Lo, Gladys Goh; Wong, Oi Lei; Yu, Siu Ki; Cheung, Kin Yin; Yuan, Jing; 'Reliability of radiomics features due to image reconstruction using a standardized T2‐weighted pulse sequence for MR‐guided radiotherapy: An anthropomorphic phantom study'. International Journal of Computer Assisted Radiology and Surgery. 2021; 12-Jan. Springer. View
Cleary, Kevin R. Periscopic Spine Surgery. Tech. no. W81XWH-04-1-0078. US Army Medical Research and Materiel Command, Fort Detrick, Maryland, Jan. 2007. Web.  2021; View
Sato I, Nakamura R, Masamune K. MRI compatible manipulator with MRI-guided needle insertion support system. In: Nagoya, Japan; 2010:77-82.  Magnetic Resonance in Medicine. 2021; Wiley Online Library. View
Jian, Chaohui; Xu, Yiting; Ma, Xiaojing; Shen, Yun; Wang, Yufei; Bao, Yuqian; 'Neck circumference is an effective supplement for nonalcoholic fatty liver disease screening in a community-based population'. 2020 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon). 2020; View
Twilt, JJ; 'Optimization of real-time imaging sequences for MR-guided percutaneous needle interventions with implementation of MR-simulations'. International Journal of Endocrinology. 2020; 2020: Hindawi. View
AlZu’bi, Shadi; Shehab, Mohammed; Al-Ayyoub, Mahmoud; Jararweh, Yaser; Gupta, Brij; 'Parallel implementation for 3d medical volume fuzzy segmentation'. 2020; University of Twente. View
AlZu'bi, Shadi; AlQatawneh, Sokyna; ElBes, Mohammad; Alsmirat, Mohammad; 'Transferable HMM probability matrices in multi‐orientation geometric medical volumes segmentation'. Pattern Recognition Letters. 2020; 130: 312-318. Elsevier. View
Thomsen, Felix SL; Delrieux, Claudio A; Pisula, Juan I; García, José M Fuertes; Lucena, Manuel; de Luis García, Rodrigo; Borggrefe, Jan; 'Noise reduction using novel loss functions to compute tissue mineral density and trabecular bone volume fraction on low resolution QCT'. Concurrency and Computation: Practice and Experience. 2020; 32 (21): e5214. Wiley Online Library. View
Xia, Mingfeng; Sun, Xiaoyang; Zheng, Lili; Bi, Yufang; Li, Qiang; Sun, Lirong; Di, Fusheng; Li, Hong; Zhu, Dalong; Gao, Yanyan; 'Regional difference in the susceptibility of non-alcoholic fatty liver disease in China'. Computerized Medical Imaging and Graphics. 2020; 86: 101816. Pergamon. View
Chen, Lingyan; Xia, Mingfeng; Wu, Li; Li, Qian; Hu, Yu; Ma, Hui; Gao, Xin; Lin, Huandong; 'Skeletal muscle loss was associated with the risk of diabetes in non non-alcoholic fatty liver disease Chinese male middle-aged and elderly population, the Shanghai Changfeng Study'. BMJ Open Diabetes Research and Care. 2020; 8 (1): e001311. BMJ Specialist Journals. View
Das M, Sauer F, Schoepf JJ, et al. Augmented reality visualization for CT-guided interventions: system description, feasibility, and initial evaluation in an abdominal phantom. Radiology. 2006; 240(1):230-235.  View
Zhang, Hui, Filip Banovac, Amy White, and Kevin Cleary. 3D Freehand Ultrasound Calibration Using an Electromagnetically Tracked Needle. Imaging Science and Information Systems Center. Department of Radiology, Georgetown University Medical Center.  View
Kroes MW, Busser WM, Fütterer JJ, et al. Assessment of Needle Guidance Devices for Their Potential to Reduce Fluoroscopy Time and Operator Hand Dose during C-Arm Cone-Beam Computed Tomography-guided Needle Interventions. J Vasc Interv Radiol. 2013;24(6):901-6.  View
Toshikuni N, Shiroeda H, Ozaki K, et al. Advanced ultrasonography technologies to assess the effects of radiofrequency ablation on hepatocellular carcinoma. Radiology and Oncology. 2013;:1-6.  View
Thapa, Bishnu Bahadur, "DEVELOPMENT OF A PATIENT SPECIFIC IMAGE PLANNING SYSTEM FOR RADIATION THERAPY" (2013).Theses and Dissertations--Physics and Astronomy.Paper 11.  View
Xia MF, Bian H, Yan HM, et al. Assessment of liver fat content using quantitative ultrasonography to evaluate risks for metabolic diseases. Obesity (Silver Spring). 2015.  View
Rathmann N, Kostrzewa M, Kara K, et al. Radiation exposure of the interventional radiologist during percutaneous biopsy using a multi-axis interventional C-arm CT system with 3D laser guidance: A phantom study. Br J Radiol. 2015;:20150151.  View
Xia MF, Lin HD, Yan HM, et al. The association of liver fat content and serum alanine aminotransferase with bone mineral density in middle-aged and elderly Chinese men and postmenopausal women. J Transl Med. 2016;14(1):11.  View
Wang D, Lin H, Xia M, et al. Vitamin D Levels Are Inversely Associated with Liver Fat Content and Risk of Non-Alcoholic Fatty Liver Disease in a Chinese Middle-Aged and Elderly Population: The Shanghai Changfeng Study. PLoS ONE. 2016;11(6):e0157515.  View
Xia MF, Yki-järvinen H, Bian H, et al. Influence of Ethnicity on the Accuracy of Non-Invasive Scores Predicting Non-Alcoholic Fatty Liver Disease. PLOS ONE. 2016;11(8):e0160526.  View
Garcia-Vazquez, V., E. Marinetto, P. Guerra, et al. "Assessment of Intraoperative 3D Imaging Alternatives for IOERT Dose Estimation." Elsevier, 23 Aug. 2016. Web.  View
Liu, J., Y. Hu, J. Yang, et al. "3D Feature Constrained Reconstruction for Low Dose CT Imaging." IEEE, Dec. 2016. Web.  View
Won, H. J., N. Kim, G. B. Kim, et al. "Validation of a CT-guided Intervention Robot for Biopsy and Radiofrequency Ablation: Experimental Study with an Abdominal Phantom." Turkish Society of Radiology, 2017. Web.  View
Lin, Xiaofeng; Zhou, Shoujun; Wen, Tiexiang; Jiang, Shenghao; Wang, Cheng; Chen, Jingtao; 'A novel multi-DoF surgical robotic system for brachytherapy on liver tumor: Design and control'. View
Long, Zaiyang; Zhou, Wei; Tradup, Donald J; Stekel, Scott F; Callstrom, Matthew R; Hangiandreou, Nicholas J; 'Systematic optimization of ultrasound grayscale imaging presets and its application in abdominal scanning'. Journal of applied clinical medical physics. 2020; 21 (10): 192-199. View

References